๐Ÿ”Œ

Distributed Energy Simulator

โ† Back to Overview

๐Ÿ“Š DER Data Format Specification

Define and validate data structures for distributed energy resources.

Device Type

Real-time Telemetry

Control Commands

JSON Schema Validator

Message Format Examples

IEC 61850 Format

<LDevice inst="Solar01"> <LN0 lnClass="LLN0"> <DOI name="Mod"> <DAI name="stVal">on</DAI> </DOI> </LN0> <LN lnClass="MMXU"> <DOI name="TotW"> <DAI name="mag.f">5200.0</DAI> </DOI> </LN> </LDevice>

SunSpec Modbus

Register Map: 40001-40002: SunSpec ID (0x53756E53) 40003-40004: Device Address 40005-40006: Model ID (101=Inverter) 40069-40070: AC Power (W) 40071-40072: AC Frequency (Hz) 40083-40084: DC Voltage (V) 40085-40086: DC Current (A)

๐Ÿงฎ Energy Management Algorithms

MPPT (Maximum Power Point Tracking)

800 W/mยฒ
25 ยฐC

Power Output

Voltage (Vmp): --
Current (Imp): --
Power Output: --
Efficiency: --

Battery State of Charge (SOC) Estimation

Current SOC

50%
Energy Available: 50 kWh
Runtime at Current Load: --

Load Balancing Algorithm

Distribute energy demand across available DER resources:

๐Ÿ”— Communication Protocol Simulator

Protocol Selection

IEC 61850

Substation automation and smart grid communication

Modbus TCP/RTU

Industrial device control and monitoring

OpenADR 2.0b

Demand response communication

IEEE 2030.5

Smart energy profile for DER integration

Message Exchange Simulation

Protocol Performance Metrics

Protocol Latency Throughput Reliability Security
IEC 61850 4-10 ms 100 Mbps 99.9% TLS 1.3
Modbus TCP 10-50 ms 10 Mbps 99.5% Optional
OpenADR 2.0b 100-500 ms 1 Mbps 99.9% TLS, X.509
IEEE 2030.5 50-200 ms 5 Mbps 99.8% TLS, ECC

โš™๏ธ Grid Integration Simulator

Microgrid Configuration

DER Assets

Solar PV: 5.2 kW
Battery: 100 kWh (75%)
Wind: 2.1 kW
Grid: Connected

Current Load

Total Demand: 6.8 kW
DER Supply: 7.3 kW
Net Import/Export: +0.5 kW Export
Power Factor: 0.98

Islanding Mode

Islanding Capability: This microgrid can disconnect from the main grid and operate independently.

Virtual Power Plant (VPP) Aggregation

Aggregate multiple DER sites into a unified resource:

Site ID Type Capacity Available Status
SITE-001 Solar + Battery 500 kW 425 kW Online
SITE-002 Wind Farm 2 MW 1.8 MW Online
SITE-003 Industrial CHP 1 MW 950 kW Online
SITE-004 EV Fleet 200 kW 150 kW Limited
Total VPP Capacity: 3.7 MW / 3.325 MW Available

๐Ÿงช System Testing & Validation

Test Scenarios

Unit Tests

  • โœ… DER data validation
  • โœ… Protocol message parsing
  • โœ… SOC calculation accuracy
  • โœ… Power flow algorithms

Integration Tests

  • โœ… Modbus communication
  • โœ… IEC 61850 GOOSE messages
  • โœ… OpenADR event handling
  • โš ๏ธ IEEE 2030.5 certification

Performance Tests

  • โœ… Message latency < 10ms
  • โœ… 1000+ devices supported
  • โœ… 99.9% uptime achieved
  • โœ… Load balancing efficiency

Run Test Suite

Compliance Validation

Standard Requirement Status Notes
IEEE 1547 Grid interconnection โœ… Pass 2018 revision compliant
UL 1741 Inverter safety โœ… Pass SA certification obtained
IEC 62040 UPS systems โœ… Pass Parts 1-3 compliant
NERC CIP Cybersecurity โš ๏ธ Pending Audit scheduled Q2

Simulation Results Export

Export test results and simulation data: