Chapter 8

Implementation & Certification

Overview

8.1 Why a wireless charger has to be certified, not just built

A cable-based charger is passive. A wireless charger is an active system that decides, many times per second, whether to keep delivering power. Its transmitter drives a coil that creates a time-varying magnetic field, and anything conductive in that field absorbs energy. That includes the intended receiver, but also a coin, a key, or tissue. A design can therefore deliver the rated wattage on the bench and still be unacceptable. It might fail to notice a metal object, drift off its resonant frequency, overheat its own winding, or talk to a receiver from another vendor in a way that vendor's firmware does not understand.

WIA-COMM-008 treats implementation and certification as one continuous path. The path has four stages:

This chapter follows that path. It starts from the formulas that testers rely on, then looks at the market segments that drive different certification burdens, and then at the test lists, design steps, and API surface that the specification provides. It closes with review questions on the calculations and decision thresholds introduced along the way.

Technical Foundation

8.2 The quantities that certification tests actually probe

Every certification item in this standard traces back to a small set of physical relationships. Inductive transfer rests on Faraday's law, and the coils are linked by mutual inductance, which depends on the coupling coefficient k (0 to 1):

V2 = M x dI1/dt
M  = k x sqrt(L1 x L2)
k  ~ (r1 x r2)^2 / [(r1 x r2)^2 + d^2]^(3/2)

The practical consequence is that k collapses as separation d grows and as the coils slide out of alignment. Efficiency and delivered power fall with it, which is why a lab measures at several alignment offsets and why chargers monitor alignment continuously. Magnetic resonance adds capacitors so that inductive and capacitive reactance cancel at the operating frequency, and the specification gives the best-case efficiency in terms of the product of coupling and quality factor:

f0    = 1 / (2 x pi x sqrt(L x C))
eta_max = (k x Q)^2 / (1 + k x Q)^2     where Q = sqrt(Q1 x Q2)

A high Q buys efficiency even when k is low, which is the basis of the longer range (up to 50 mm, against about 10 mm for simple induction) and the greater positional freedom of resonant systems.

Qi builds its protocol on top of this physics. The receiver talks to the transmitter by load modulation at 2 kHz with a data rate of 2 kbps. Each packet has the following layout:

[Preamble] [Header] [Message]     [Checksum]
  11 bits   1 byte   0-27 bytes    1 byte

A session moves through six phases: selection, ping, identification, configuration, power transfer, and renegotiation. The transmitter's operating frequency is stepped as f = f_base + (n x 64) Hz, with n from 0 to 1470. The base is 110 kHz for BPP and 87 kHz for EPP, and the valid ranges end at 205 kHz. The profiles a tester must distinguish are:

ProfilePowerFrequencyVoltageTypical devices
BPP (Baseline)0-5 W110-205 kHz5 V, up to 1 ABasic phones, accessories
EPP (Extended)5-15 W110-205 kHz9 V, 12 V, up to 1.67 AFast-charging phones
Qi v1.3Up to 30 W87-205 kHz-Laptops, tablets

AirFuel takes a different route. It operates at 6.78 MHz in the ISM band with a Class-E amplifier topology, delivers up to 50 W over 0-50 mm, and uses a Bluetooth Low Energy side-channel for pairing and control.

Market Analysis

8.3 Three segments, three certification burdens

The specification organizes the field into segments, each with its own governing body and its own cost of entry. In consumer electronics, Qi from the Wireless Power Consortium is described as the most widely adopted standard. A charger or phone maker in this segment is expected to carry a WPC Qi certification number. AirFuel Alliance, formed from the Alliance for Wireless Power and the Power Matters Alliance, occupies the resonant, higher-frequency niche with its own certification. In electric vehicles, SAE J2954 defines power classes and ground-to-vehicle alignment tolerances.

Efficiency and range differ sharply between these segments. The specification's typical figures show how each technology trades distance against loss:

Power levelTechnologyEfficiencyDistance
5 WQi BPP70-75%3-5 mm
15 WQi EPP75-80%3-8 mm
50 WAirFuel65-75%10-50 mm
11 kWSAE J295485-90%100-200 mm

Two commercial consequences follow. First, compatibility is a market problem as well as a technical one. The session API rejects a pairing in which a Qi-only charger meets an AirFuel-only receiver, unless the charger advertises multi-protocol support. A vendor that wants a charger to serve both camps must therefore pass both certification programs. Second, the highest-efficiency segment is also the one where small percentage losses become large heat loads, which is why EV certification leans heavily on alignment tolerance and field-exposure compliance.

Industry Applications

8.4 Where the certified behaviours matter in practice

Smartphones are the best-known case. A BPP phone and an EPP charger negotiate during the configuration phase, and the charger must fall back to the lower profile instead of forcing a power level the receiver cannot take. Laptops and tablets motivate the Qi v1.3 medium-power profile, with up to 30 W. Desk and car-console chargers motivate the multi-device architectures. A multi-coil array of 3 to 9 coils gives each device a dedicated coil. A single large coil shares one field among devices at lower efficiency. A guided-positioning layout uses one to three coils with mechanical guides and keeps efficiency high through alignment. Where the supply is limited, the specification allocates power by a simple rule:

P_i = min(P_requested_i, P_max / N)

Time-division multiplexing between coils, at a switching frequency of 10-100 Hz, is the alternative that simplifies the power electronics.

In vehicles, SAE J2954 defines four power classes:

ClassPowerVoltageUse case
WPT13.7 kW400 VPHEV, small BEV
WPT27.7 kW400 VPassenger BEV
WPT311 kW400 VLarge BEV
WPT422 kW800 VFast charging

The ground assembly is a 500-800 mm coil embedded in pavement, operating at 85 kHz. The vehicle assembly sits under the car with 100-250 mm of ground clearance. Alignment tolerance is part of the class definition: ±75 mm for WPT2 and ±100 mm for WPT3. Dynamic charging, with in-road coils switched on as a vehicle passes, is described for electric buses and autonomous shuttles at 20-100 kW per vehicle.

Standards Compliance

8.5 What each certification program checks, and how the record is exposed

The specification lists the tests per program. WPC Qi certification covers six areas: power transfer at the BPP/EPP levels, communication packet structure and timing, minimum efficiency targets, detection of standard metal objects, EMI/EMC, and safety (temperature, overcurrent, overvoltage). AirFuel certification checks the resonant frequency (6.78 MHz ±5%), BLE pairing and control, simultaneous multi-device charging, and EMF and thermal limits. Cross-platform testing then runs devices against multiple charger brands, several power levels, various alignment offsets, and a temperature range of -10°C to 45°C. A product that passes in one lab setup but fails with a rival's receiver has not demonstrated interoperability.

Field-exposure limits are a separate compliance track. For the 110-205 kHz Qi band, the specification quotes ICNIRP (2010) reference levels of 6.25 μT (RMS) for the magnetic field, 83 V/m (RMS) for the electric field, and a localized SAR of 2 W/kg. For IEEE C95.1 (2019), covering 3 kHz to 10 MHz, it quotes 27 μT and 614 V/m. Designers estimate the field with the single-loop expression B(d) ≈ (μ0 x N x I x r²) / [2 x (r² + d²)^(3/2)] and reduce it using ferrite behind the coil, aluminum shielding around sensitive electronics, more distance, or lower current.

The standard's one cross-cutting software element is the conformance endpoint. GET /wireless-charging/v1/conformance/{id} returns the charger's certification envelope in one place:

A fleet operator can then verify a charger's standing before enrolling it, without collecting paper certificates.

Implementation Considerations

8.6 Design steps, safety loops, and the session interface

The specification's transmitter checklist reads as a sequence of decisions. Choose a power level (BPP 5 W, EPP 15 W, or higher). Choose a frequency family (about 110 kHz for Qi, 6.78 MHz for AirFuel). Design the coil by calculating turns, wire gauge, and ferrite. Add foreign object detection, add an NTC thermistor in the coil, and design the power electronics (full-bridge inverter and controller). Finally, implement the communication path: demodulating backscatter for Qi, or BLE for AirFuel. Efficiency work follows the same logic. It includes impedance matching, tuning to resonance, minimizing misalignment, high-Q coils built with litz wire and ferrite, and active rectification with synchronous FETs in place of diodes. The loss budget has three parts: coil resistance (I²R), core hysteresis and eddy currents, and rectifier dissipation.

Foreign object detection is the check that most often makes or breaks a certification run. The specification gives three methods with example thresholds:

MethodMeasured quantityFlag threshold
Q-factorΔQ = (Q_baseline - Q_measured) / Q_baseline> 10%
Power lossP_in - P_out - P_expected_loss> 1 W
Frequency detuningf_baseline - f_measured> 2%

The Qi implementation calibrates a baseline Q with no object present, re-checks Q every second, cuts power on detection, and notifies the user by LED, beep, or app. Foreign objects can heat dangerously, above 100°C, so this is a safety function as well as an efficiency one. Thermal supervision runs in parallel. NTC thermistors embedded in the transmitter coil are sampled at 1-10 Hz, with a warning at 70°C and a cutoff at 80°C. Alignment feedback through LED color, beep rate, tone pitch, or haptic pulses helps the user keep k high.

The interface layer makes these loops observable. The Phase 2 endpoints are:

POST /wireless-charging/v1/chargers              # register charger
GET  /wireless-charging/v1/chargers/{id}         # fetch charger record
POST /wireless-charging/v1/sessions              # start charging session
GET  /wireless-charging/v1/sessions/{id}/state   # current session state
POST /wireless-charging/v1/sessions/{id}/stop    # stop session
WS   /wireless-charging/v1/telemetry/stream      # power/temperature telemetry
GET  /wireless-charging/v1/conformance/{id}      # WPC/AirFuel/J2954 cert status

The session state machine is negotiating, ramping, charging, topping-off, complete, and three abort states: aborted-fod, aborted-thermal, and aborted-misalignment. The abort states record why a session ended, so a field failure can be matched to the physical cause. The telemetry stream carries Tx and Rx power, efficiency, coil temperatures, FOD status, an alignment estimate (X/Y offset in mm, plus tilt where supported), and state-of-charge progress. It also emits alarm events on FOD detection, thermal threshold crossing, or alignment loss beyond policy. Session starts are rate-limited per charger to 10 per minute, which the specification gives as a defence against coil-thermal abuse.

Future Outlook

8.7 Directions that follow from the specification's own scope

The standard's scope statement already points to where certification effort is heading. At the consumer end, Qi has stepped from 5 W through 15 W to a 30 W medium-power profile, and the specification covers high-power wireless charging at 50 W and above. Each step raises the heat and field the transmitter must manage. The foreign object and thermal tests that were comfortable at 5 W become more demanding as power rises, and they will probably receive more attention in future test plans.

Spatial freedom is the second direction. Multi-coil arrays, AirFuel zone chargers, and the Qi spatial-freedom arrays at 15-22 W mentioned in the API section all try to make alignment a non-issue. In these systems the interface exposes per-device coil allocation, per-device power envelopes, and a cross-talk envelope, and certification must account for several receivers coupling at once. The third direction is EV charging. The WPT4 class at 22 kW and 800 V, and dynamic charging at 20-100 kW, move the application from parking spaces to roadways. For those systems, alignment tolerance, field exposure around the vehicle, and ground-assembly durability become the main certification concerns. None of these developments changes the basic structure described in this chapter: physics sets the limits, the protocol negotiates within them, safety loops enforce them, and a conformance record proves it.

Review Questions

8.8 Questions for self-assessment

  1. A resonant link has kQ = 9. Using the strongly-coupled resonance expression, what is η_max? What happens to the result if k halves and Q is unchanged?
  2. A Qi transmitter calibrated its baseline Q at 100. During operation it measures 85. By the Q-factor method, does this indicate a foreign object? State the threshold.
  3. Explain why the specification gives the power-loss FOD method a fixed 1 W threshold, and describe a situation in which Q-factor and power-loss detection could disagree.
  4. Three phones request 15 W, 5 W and 15 W from a charger with a 30 W maximum. Apply P_i = min(P_requested_i, P_max / N) and report each allocation. Does the rule hand the unused share of the 5 W device to the others?
  5. List the six Qi power-transfer phases in order, and say in which phase a receiver learns what power level it may draw.
  6. A charger returns an aborted-misalignment state for a WPT3 installation. Which physical quantity declined, and what alignment tolerance does the specification give for that class?
  7. Why might a Qi-only charger legitimately reject a session with an AirFuel-only receiver, and what must the charger advertise to avoid that rejection?

Summary

8.9 Summary and the road ahead

Certification in wireless charging is the point at which the physics, the protocol, and the safety loops are checked together. The coupling coefficient and quality factor explain the efficiency figures. Qi's packet-based negotiation and AirFuel's BLE side-channel explain how devices agree on power. Q-factor, power-loss, and detuning checks, along with thermal limits at 70°C and 80°C, explain how a charger knows when to stop. WPC, AirFuel, and SAE J2954 programs, together with EMC and field-exposure references, define what a passing product looks like. The conformance endpoint and the telemetry stream expose all of this to software, so the evidence is queryable instead of buried in a test report.

The next chapter picks up after a product has passed. It looks at what happens once chargers are deployed at scale, where the interest shifts from a one-time test to ongoing evidence. Session states, alarm events, and thermal and alignment readings must keep showing that fielded units still behave as they did in the lab.